產品介紹∣Ruggedized Outdoor Data Acquisition System
Search

Ruggedized Outdoor Data Acquisition System

【Elsys】多通道資料蒐集器 多通道資料蒐集器

Ruggedized Outdoor Data Acquisition System

簡介

RODAS

RODAS測量系統是適用於惡劣戶外應用的DAQ解決方案。 防護等級為IP65的機箱可以容納TraNET FE DAQ單元,UPS,網絡交換機,SyncLink同步單元以及加熱或冷卻元件的不同配置。

我要諮詢

RODAS測量系統是適用於惡劣戶外應用的DAQ解決方案。 防護等級為IP65的機箱可以容納TraNET FE DAQ單元,UPS,網絡交換機,SyncLink同步單元以及加熱或冷卻元件的不同配置。

  • 防護等級IP 65
  • 具有冷卻/加熱系統的設計
  • 適用-30°~50°的環境溫度
  • 濕度:<80%RH,無凝結
  • UPS不間斷操作

★ 詳細規格請洽詢,我們將有專業人員為您服務!

Connection Ethernet 1 GBit, RJ45 front connector
Harddisk 200 GB SSD
Power Supply 10 - 36 V DC
Powerplug: SFV 40 0 (IEC 60130-9)
Power Consumption ~ 30 - 60 W
(depend on the installed DAQ card)
Operating Condition 0 .. 35 °C
Higher temperature possible when free air flow is applied over the instrument.
Rel. Humidity:
- Up to 31°C: < 80% ,
- 31°C ..45°C: decreasing to < 50%
Max. Operating Elevation: 2’000m
Storage Temperature -20 .. 60 °C
Channel Configuration 8 / 16 / 24 / 32 single ended
Recording Modes Scope, Multi Block, Continuous, Event Controlled Recording (ECR),
Dual Sampling Rate (with ECR only)
Digital IO‘s (TTL) Trigger In, Trigger Out, External Timebase In, Disarm In, Armed Out, SyncClock Out Optional: 8 Digital Marker Inputs
Synchronisation SyncLink Port, Pulse per Second Sync Optional: GPS
Software TranAX 4 LE, TranAX 4 LabVIEW Instrument Driver C++/C#/Python API
Mechanical Specification 330 x 115 x 289 mm
6.1 kg (32 channels)

The RODAS measurement system is a DAQ solution for harsh outdoor applications. The IP65 protected chassis can hold different configuration of TraNET FE DAQ instruments, UPS, network switches,SyncLink synchronization units and heating or cooling elements. 

Key Specification

  • IP 65 protected case
  • Integrated cooling/heating system
  • -30° to 50° environment temperature supported
  • Humidity: < 80% RH, non condensing
  • UPS for uninterrupted operation

★ 詳細規格請洽詢,我們將有專業人員為您服務!

Connection Ethernet 1 GBit, RJ45 front connector
Harddisk 200 GB SSD
Power Supply 10 - 36 V DC
Powerplug: SFV 40 0 (IEC 60130-9)
Power Consumption ~ 30 - 60 W
(depend on the installed DAQ card)
Operating Condition 0 .. 35 °C
Higher temperature possible when free air flow is applied over the instrument.
Rel. Humidity:
- Up to 31°C: < 80% ,
- 31°C ..45°C: decreasing to < 50%
Max. Operating Elevation: 2’000m
Storage Temperature -20 .. 60 °C
Channel Configuration 8 / 16 / 24 / 32 single ended
Recording Modes Scope, Multi Block, Continuous, Event Controlled Recording (ECR),
Dual Sampling Rate (with ECR only)
Digital IO‘s (TTL) Trigger In, Trigger Out, External Timebase In, Disarm In, Armed Out, SyncClock Out Optional: 8 Digital Marker Inputs
Synchronisation SyncLink Port, Pulse per Second Sync Optional: GPS
Software TranAX 4 LE, TranAX 4 LabVIEW Instrument Driver C++/C#/Python API
Mechanical Specification 330 x 115 x 289 mm
6.1 kg (32 channels)