產品介紹∣單相交流電流源
Search
單相交流電流源

簡介

CC11

The CC11 is single phase AC current source class 0.2 with signal frequency equal to 50/60Hz and with phase shift 0° or 180° relative to the supply voltage. The CC11 enables to generate current in range up to 5A at the supply voltage 85..264V

我要諮詢
  • Loading of single and three phase electricity meters
  • Current setting range from 0.005 to 5.000A
  • Digital measurement of output current
  • Silent operation and no heating
  • No need to disconnect meter and end user from circuit during electricity meter testing on site
  • Powering directly from measurement circuit
  • Galvanically isolated output
  • Accuracy class 0.2 for testing of AC current devices

Parameter

Value 1)

Current setting range

0.005…5A

Resolution of current setting

0.001A

Current setting error and current measurement error

±0.2% @ 0.5...5A   and   ±0.2%* @ 0.005 0.5A

Maximum load

1.5V @ 5A

Phase angle of the output current relative to the supply voltage

0° ±2° @ 230V

Frequency

50/60Hz according to the supply voltage

THD of current

according to the supply voltage

Supply voltage

85...264VAC / 45...65Hz / 25VA

Ambient temperature

-10...+60°C operating,
-20...+60°C transportation

Dimensions (width/height/depth) and weight

110 / 190 / 80mm and 1.2kg

Measurement Category

300V CAT III acc. to EN 61010-1

Degree of protection

IP40 acc. to EN 60529

1) % - related to the measuring value, %* - related to the measuring final value

  • Loading of single and three phase electricity meters
  • Current setting range from 0.005 to 5.000A
  • Digital measurement of output current
  • Silent operation and no heating
  • No need to disconnect meter and end user from circuit during electricity meter testing on site
  • Powering directly from measurement circuit
  • Galvanically isolated output
  • Accuracy class 0.2 for testing of AC current devices

Parameter

Value 1)

Current setting range

0.005…5A

Resolution of current setting

0.001A

Current setting error and current measurement error

±0.2% @ 0.5...5A   and   ±0.2%* @ 0.005 0.5A

Maximum load

1.5V @ 5A

Phase angle of the output current relative to the supply voltage

0° ±2° @ 230V

Frequency

50/60Hz according to the supply voltage

THD of current

according to the supply voltage

Supply voltage

85...264VAC / 45...65Hz / 25VA

Ambient temperature

-10...+60°C operating,
-20...+60°C transportation

Dimensions (width/height/depth) and weight

110 / 190 / 80mm and 1.2kg

Measurement Category

300V CAT III acc. to EN 61010-1

Degree of protection

IP40 acc. to EN 60529

1) % - related to the measuring value, %* - related to the measuring final value