簡介
7310 / 7315
網頁資料建構中
網頁資料建構中
The 73 series introduces four new spectrophotometers to the extensive Jenway range. These spectrophotometers use icon driven software and have an improved navigation system for easy and intuitive usability. The range includes two basic models, 7300 and 7305 and two advanced models, 7310 and 7315. The 7310 and 7315 feature measurement modes for absorbance, % transmittance, concentration, spectrum scanning, kinetics and quantitation.
The advanced models have the additional feature of an easy access USB port on the front of the unit which enables results to be stored directly to a USB memory stick for easy transfer of data. These models can also store up to 240 methods which can be copied from one unit to another using the USB capability.
The 7310 and 7315 models have enhanced security features enabling the settings and methods to be locked preventing unauthorised changes to the instrument settings and method parameters. The home page can also be customised and selected modes restricted, which is ideal for teaching laboratories.
Parameter | 7310 | 7315 |
Wavelength Range | 320 to 1000nm | 198 to 1000nm |
Light source | Tungsten halogen lamp | Xenon lamp |
Resolution | 1nm | 1nm |
Accuracy | ± 2nm | ± 2nm |
Repeatibility | ± 0.5nm | ± 0.5nm |
Spectral bandwidth | 5nm | 5nm |
Photometric Transmittance | 0 to 199.9% | 0 to 199.9% |
Photometric Absorbance | -0.300 to 2.500 | -0.300 to 2.500 |
Photometric Accuracy | ± 1%T, ± 0.01Abs at 1.000 Absorbance | ± 1%T, ± 0.01Abs at 1.000 Absorbance |
Photometric Resolution | 0.1%T, 0.001A | 0.1%T, 0.001A |
Concentration Range | -300 to 9999 | -300 to 9999 |
Concentration Resolution | selec table 1/ 0.1/ 0.01/ 0.001 | selec table 1/ 0.1/ 0.01/ 0.001 |
Concentation Calibration | Blank with a single standard or factor | Blank with a single standard or factor |
Concentration Units | no units, %, ppm, EBC, SRM, mEq/l, mEq, M, mM, µM, nM, U, U/l, U/ml, g/l, mg/l, µg/l, ng/l, g/dl, mg/dl, µg/dl, mg/ml, µg/ml, ng/ml, µg/ul, ng/ul, mol/l, mmol/l | no units, %, ppm, EBC, SRM, mEq/l, mEq, M, mM, µM, nM, U, U/l, U/ml, g/l, mg/l, µg/l, ng/l, g/dl, mg/dl, µg/dl, mg/ml, µg/ml, ng/ml, µg/ul, ng/ul, mol/l, mmol/l |
Concentration Factor | 0.001 to 10000 | 0.001 to 10000 |
Concentration Standard | 0.001 to 1000 | 0.001 to 1000 |
Quantitation Range | -300 to 9999 | -300 to 9999 |
Quantitation Resolution | selec table 1/ 0.1/ 0.01/ 0.001 | selec table 1/ 0.1/ 0.01/ 0.001 |
Quantitation Calibration | Blank with up to 6 standards | Blank with up to 6 standards |
Quantitation Curve fit algorithms | Quadratic, quadratic through zero, linear, linear through zero, interpolate | Quadratic, quadratic through zero, linear, linear through zero, interpolate |
Kinetics Measurement time | 2 to 9999 seconds | 2 to 9999 seconds |
Kinetics Calibration | Blank with a single standard or factor | Blank with a single standard or factor |
Kinetics Display | Graphical and concentration | Graphical and concentration |
Kinetics Analysis | Concentration, rate of change, initial and final absorbance/%T | Concentration, rate of change, initial and final absorbance/:%T |
Kinetics Resolution | selec table 1/ 0.1/ 0.01/ 0.001 | selec table 1/ 0.1/ 0.01/ 0.001 |
Spectrum Range | 320 to 1000nm | 198 to 1000nm |
Spectrum Scan interval | selec table 1, 2 or 5nm | selec table 1, 2 or 5nm |
Spectrum Analysis | Absorbance or transmittance and peak and valleys | Absorbance or transmittance and peak and valleys |
GLP | Current time and date, user ID, instrument lock and method lock | Current time and date, user ID, instrument lock and method lock |
Method storage | 240 | 240 |
Results memory | Limited by attached mass storage device | Limited by attached mass storage device |
Removable media | USB (supplied) | USB (supplied) |
Outputs | USB, Analogue, RS232, Integral printer | USB, Analogue, RS232, Integral printer |
Size (w x d x h) | 275 x 400 x 220mm | 275 x 400 x 220mm |
Weight | 6kg | 6kg |