產品介紹∣EmStat 4S恆電位|恆電流|阻抗分析儀 (FRA 200kHz)
Search

EmStat 4S恆電位|恆電流|阻抗分析儀 (FRA 200kHz)
POTENTIOSTAT / GALVANOSTAT / IMPEDANCE ANALYZER

【PalmSens】攜帶型電化學儀器 單通道恆電位儀系列

EmStat 4S恆電位|恆電流|阻抗分析儀 (FRA 200kHz)

簡介

EmStat 4S

EmStat4S 是一款便攜式 USB 供電的恆電位儀、恆電流儀和電化學阻抗的可選頻率響應分析儀 (FRA 200kHz)。EmStat4S 有兩個版本:LR(小電流)和HR(大電流)版本。

我要諮詢

EmStat4S 是一款便攜式 USB 供電的恆電位儀、恆電流儀和電化學阻抗的可選頻率響應分析儀 (FRA 200kHz)。
EmStat4S 有兩個版本:LR(小電流)和HR(大電流)版本。
LR可達 1 nA 的低電流範圍,最高電流10mA;而HR版本非常適合需要高達 200 mA 的最大電流的應用。

 

 

 

 

EmStat 4S LR(小電流)

EmStat4S  HR(大電流)

Potential range

±3 V

±6 V

Max. compliance voltage

±5 V

±8 V

Current ranges

1 nA to 10 mA (8 ranges)

100 nA to 100 mA (7 ranges)

Max. current

±30 mA

±200 mA

Electrode connections

WE, RE, CE,
and ground,
2 mm banana plugs

WE, RE, CE, S,
and ground,
2 mm banana plugs

General

model

LR

HR

dc-potential range

±3 V

±6 V

compliance voltage

±5 V

±8 V

maximum current

±30 mA

±200 mA

max. data acquisition rate

1M samples/s

 

Potentiostat (controlled potential mode)

model

LR

HR

applied potential resolution

100 µV

183 µV

applied potential accuracy

≤ 0.2% ±1 mV offset

 

current ranges

1 nA to 10 mA
8 ranges

100 nA to 100 mA
7 ranges

measured current resolution

0.009% of CR (92 fA on 1 nA range)

measured current accuracy

≤ 0.2% at Full Scale Range

Galvanostat (controlled current mode)

model

LR

HR

current ranges

10 nA, 1 uA,
100 uA, 10 mA
4 ranges

1 uA, 100 uA,
10 mA, 100 mA
4 ranges

applied dc-current

±3 * CR (current range)

applied dc-current resolution

0.01% of CR

0.0183% of CR

applied dc-current accuracy

<0.4% (gain) +
0.002 * CR (offset)

<0.4% (gain) +
0.002 * CR (offset)

measured dc-potential resolution

96 µV (gain 1)
48 µV (gain 2)
19.2 µV (gain 5)
9.6 µV (gain 10)
4.8 µV (gain 20)

193 µV (gain 1)
96.5 µV (gain 2)
38.5 µV (gain 5)
19.3 µV (gain 10)
9.65 µV (gain 20)

measured dc-potential accuracy

≤ 0.2% ±1 mV offset

 

FRA / EIS (impedance measurements)

frequency range

10 µHz to 200 kHz

ac-amplitude range

1 mV to 900 mV rms, or 2.5 V p-p

GEIS (galvanostatic impedance measurements)

frequency range

10 µHz to 200 kHz

ac-amplitude range

0.9 * CR A rms

Electrometer

electrometer amplifier input

> 1 TΩ // 10 pF

bandwidth

10 kHz default or
500 kHz for EIS and fast CA/CP

Other

model

LR

HR

electrode connections

WE, RE, CE,
and ground,
with 2 mm banana plugs

WE, RE, CE, S
and ground,
with 2 mm banana plugs

housing

aluminum body: 7.2 x 5.5 x 2.6 cm3

 

weight

+/- 130 g

 

power + communication

USB-C port

 

internal storage space

500 MB, equivalent to >15M datapoints

The EmStat4S is a portable USB-powered Potentiostat, Galvanostat, and optional Frequency Response Analyser (FRA) for Electrochemical Impedance Spectroscopy (EIS). The EmStat4S Low Range version is great for applications that require a low current range down to 1 nA, whereas the High Range version is very suitable for applications that need a maximum current of up to 200 mA.

The EmStat4S is available in two versions: the LR (Low Range) and HR (High Range) versions. The following table shows the main differences:

 

 

 

 

EmStat 4S LR(小電流)

EmStat4S  HR(大電流)

Potential range

±3 V

±6 V

Max. compliance voltage

±5 V

±8 V

Current ranges

1 nA to 10 mA (8 ranges)

100 nA to 100 mA (7 ranges)

Max. current

±30 mA

±200 mA

Electrode connections

WE, RE, CE,
and ground,
2 mm banana plugs

WE, RE, CE, S,
and ground,
2 mm banana plugs

General

model

LR

HR

dc-potential range

±3 V

±6 V

compliance voltage

±5 V

±8 V

maximum current

±30 mA

±200 mA

max. data acquisition rate

1M samples/s

 

Potentiostat (controlled potential mode)

model

LR

HR

applied potential resolution

100 µV

183 µV

applied potential accuracy

≤ 0.2% ±1 mV offset

 

current ranges

1 nA to 10 mA
8 ranges

100 nA to 100 mA
7 ranges

measured current resolution

0.009% of CR (92 fA on 1 nA range)

measured current accuracy

≤ 0.2% at Full Scale Range

Galvanostat (controlled current mode)

model

LR

HR

current ranges

10 nA, 1 uA,
100 uA, 10 mA
4 ranges

1 uA, 100 uA,
10 mA, 100 mA
4 ranges

applied dc-current

±3 * CR (current range)

applied dc-current resolution

0.01% of CR

0.0183% of CR

applied dc-current accuracy

<0.4% (gain) +
0.002 * CR (offset)

<0.4% (gain) +
0.002 * CR (offset)

measured dc-potential resolution

96 µV (gain 1)
48 µV (gain 2)
19.2 µV (gain 5)
9.6 µV (gain 10)
4.8 µV (gain 20)

193 µV (gain 1)
96.5 µV (gain 2)
38.5 µV (gain 5)
19.3 µV (gain 10)
9.65 µV (gain 20)

measured dc-potential accuracy

≤ 0.2% ±1 mV offset

 

FRA / EIS (impedance measurements)

frequency range

10 µHz to 200 kHz

ac-amplitude range

1 mV to 900 mV rms, or 2.5 V p-p

GEIS (galvanostatic impedance measurements)

frequency range

10 µHz to 200 kHz

ac-amplitude range

0.9 * CR A rms

Electrometer

electrometer amplifier input

> 1 TΩ // 10 pF

bandwidth

10 kHz default or
500 kHz for EIS and fast CA/CP

Other

model

LR

HR

electrode connections

WE, RE, CE,
and ground,
with 2 mm banana plugs

WE, RE, CE, S
and ground,
with 2 mm banana plugs

housing

aluminum body: 7.2 x 5.5 x 2.6 cm3

 

weight

+/- 130 g

 

power + communication

USB-C port

 

internal storage space

500 MB, equivalent to >15M datapoints