簡介
PAT-Clamp-1
Single channel docking station with minimized dimensions
Docking station with minimized dimensions
Product description
The PAT-Clamp-1 is our smallest docking station for a single PAT test cell. It was developed for tight space constraints. The socket can be left connected permanently to a common potentiostat or battery tester using 2 mm banana sockets or Sub-D connector. Therefore there is no need to renew the connection between cell and potentiostat for every battery test. It also fits perfectly into any climate chamber with a cable feed-through and can be placed inside a glovebox. The cell is inserted and removed by bending up the clamp.
The PAT-Clamp-1 is available in two variants, that differ only in the alignment of the Sub-D connector.
The PAT-Clamp-1 allows immediate functional testing of all PAT series test cells with smallest possible footprint. Typically, it is used in combination with a high-throughput solution. For instance, 16 PAT-Cells can be cycled in parallel in a PAT-Chamber-16 connected by a third-party battery tester without impedance capability. In that case, the impedance of each test cell can be measured before and after the cycle test in the PAT-Clamp-1 connected to the PAT-Tester-x or another impedance analyzer.
Schematic view of a connected PAT-Clamp-1 testing a PAT-Cell
Schematic view of a connected PAT-Clamp-1 testing a PAT-Cell-Press
Gallery
EL-CELL PAT-Cell-Gas connected to a PAT-Clamp-1 H.
Size comparison PAT-Stand-1 and PAT-Clamp-1
ECD-4-nano setup inside a temperature chamber.
Complete battery test setup for above 40°C.
PAT-Clamp-1 V | |
Height | 27/83 mm (without/with PAT-Cell-Press) |
Width | 80 mm |
Depth | 62 mm |
Weight | 0.12 kg (without cell) |
Operating temperature | -20 to +70°C |
PAT-Clamp-1 H | |
Height | 27/83 mm (without/with PAT-Cell-Press) |
Width | 86 mm |
Depth | 62 mm |
Weight | 0.12 kg (without cell) |
Operating temperature | -20 to +70°C |
Name | # Cell connections (PAT Socket) | Operational temperature | Temperature controlled cell chamber | Charge / Discharge / EIS* | Data Logger*** | Measurements in mm (Height/Width/Length) |
---|---|---|---|---|---|---|
PAT-Clamp-1 | 1 | -20 - 70 ° C | Yes | 21 / 62 / 80 | ||
PAT-Stand-1 | 1 | -20 - 70 ° C | Yes | 80 / 113 / 105 | ||
PAT-Stand-4 | 4 | -20 - 70 ° C | Yes | 84 / 119 / 301 | ||
PAT-Heater-4 | 4 | up to 200 ° C** | Yes | 230 / 265 / 400 | ||
PAT-Stand-16 | 16 | -20 - 70 ° C | Yes | Yes | 120 / 315 / 315 | |
PAT-Chamber-16 | 16 | 10-80 ° C | Yes | Yes | 375 / 640 / 380 |
* Compatible with any PAT series test cell
** 10 °C above average room temperature to 200 °C
*** Independent data acquisition of cell data (current, full- and half-cell voltages), pressure (only PAT-Chamber-16) and temperature. EC-Link monitoring software is provided.